What Is Functional Safety? Standards, Lifecycle and Safety Levels

Chapters

Chapter 7: What Is Functional Safety? Standards, Lifecycle and Safety Levels

Chapters

What Is Functional Safety? Standards, Lifecycle and Safety Levels

Functional safety is the part of a system’s overall safety that depends on its electrical, electronic and software-based safety functions working correctly, so that the system detects a dangerous condition and moves to a safe state. Engineers achieve it by rating each hazard, assigning each safety function a required integrity level, and showing with verification evidence that the function meets that level.

Current verification evidence gives you a basis for a functional safety (FuSa) assessment. For an engineer moving into safety-critical work, keeping that evidence current is the work that continues for as long as the system is in service.

One changed requirement or hazard rating can invalidate analyses and tests that were complete the week before, so the links from each hazard to its safety requirements and test evidence need to stay current. You’ll learn which standards apply, what integrity ratings mean and how to maintain verification evidence throughout the lifecycle.

What Does Functional Safety Mean in Practice?

Functional safety covers the automatic responses that move equipment to a safe condition when something goes wrong. In a car, it makes an airbag deploy on impact and stay folded during normal vehicle operation. On a train, subway or cable car, it keeps the doors closed while the vehicle moves. In a tank of flammable liquid, a level switch that closes a valve when the liquid reaches a dangerous level is a safety function.

IEC 61508 is the cross-industry functional safety standard. Four of its terms come up whenever you write safety requirements:

  • Equipment under control (EUC): The EUC is the equipment, machinery, apparatus or plant that gives rise to the hazardous events a safety-related system is required to protect against. Its control system is treated separately.
  • Safety function: A safety function is a function, carried out by an electrical, electronic and programmable electronic (E/E/PE) safety-related system or another risk reduction measure, that puts or keeps the EUC in a safe state when a specific hazardous event occurs. Switching off a motor and preventing a motor from starting are both examples.
  • Safe state: A safe state is the state of the EUC when safety is achieved. A safety function may put the EUC into a safe state or hold it there.
  • Safety-related system: A safety-related system is everything, including hardware, software and human elements, needed to carry out one or more safety functions where failure would significantly increase risk. It can be dedicated equipment, such as the level switch and valve on a flammable-liquid tank, or part of a larger machine’s control system.

The definitions make functional safety a requirements problem from the first day, since a safety function is something a system has to do under stated conditions and to a stated level of performance. General product safety is broader, covering passive measures such as insulation as well. An example of the boundary between the two is a railway level crossing.

The control logic that lowers the barrier and flashes the warning lights when a train approaches belongs in the functional safety analysis, because it has to detect a condition and act. By contrast, the mechanical strength of the barrier arm belongs in the general product safety analysis, because it protects users without any function having to execute.

Which Functional Safety Standards Apply in Each Industry?

IEC 61508 is the base functional safety standard for E/E/PE safety-related systems irrespective of where and how they are used, including products with no sector-specific standard. Sector standards adapt it to an industry’s hazards and vocabulary, so teams selling into multiple sectors are typically expected to meet each sector’s standard and the integrity scale it uses. Medical device software adds IEC 62304, which grades its software safety classes A, B and C by the severity of possible harm.

Automotive: ISO 26262

Road vehicle programs follow ISO 26262, a functional safety process for electrical and electronic systems in vehicles. ISO 26262 was adapted from IEC 61508. Its second edition, ISO 26262:2018, is current. The automotive sector does not use IEC 61508’s Safety Integrity Level (SIL) determination and instead rates hazards on the Automotive Safety Integrity Level (ASIL) scale from A to D. Under ISO 26262, a supplier can be asked for safety evidence for the parts it develops.

Industrial Process and Machinery: IEC 61511, ISO 13849-1 and IEC 62061

Process plants apply IEC 61511 to safety instrumented systems (SIS). IEC 61511 is the process sector’s implementation of IEC 61508. You must specify, design, install, operate and maintain an SIS so that it reliably achieves or holds a safe state of the process (IEC 61511 Part 1).

Machinery control systems follow one of two standards. ISO 13849-1:2023 covers safety-related parts of control systems in high demand and continuous modes, whatever their technology, including electrical, hydraulic, pneumatic or mechanical systems. Low demand mode is outside the scope of ISO 13849-1. IEC 62061:2021 is a machinery sector specific standard within the IEC 61508 framework.

Rail: EN 50126, EN 50129 and EN 50716

Rail programs manage reliability, availability, maintainability and safety (RAMS) through a process for managing RAMS based on the system life cycle under EN 50126. EN 50129 applies to safety-related electronic systems for signalling.

Railway software engineers follow process and technical requirements under EN 50716:2023 when developing software for signaling applications and on board rolling stock. EN 50716 supersedes EN 50128:2011 for signalling software and EN 50657 for rolling stock software. Because sector standards can use different integrity scales, a safety requirement is rated on the scale of the standard it is written against.

How Does ISO 26262 Define Functional Safety for Road Vehicles?

Under ISO 26262, functional safety is the absence of unreasonable risk due to hazards caused by malfunctioning behavior of electrical and electronic (E/E) systems. ISO 21448, the safety of the intended functionality (SOTIF) standard, covers a system that works as designed but still behaves unsafely, and it doesn’t apply to faults covered by ISO 26262.

ISO 26262:2018 applies to safety-related E/E systems installed in series-production road vehicles. Hazards such as electric shock, fire, smoke, heat, radiation or toxicity are within its scope only when a malfunction of a safety-related E/E system directly causes them. The nominal performance of E/E systems is outside its scope as well.

When applying ISO 26262, you describe the item, its hazards and its safety requirements in these terms:

  • Malfunctioning behaviour: Malfunctioning behaviour is a failure or unintended behaviour of an item.
  • Hazard: A hazard is a potential source of harm caused by that behaviour.
  • Item definition: The item definition is the concept-phase description of the item, its environment and its boundary.
  • Safety goal: A safety goal is the top-level safety requirement that engineers derive for each hazard through hazard analysis and risk assessment (HARA), with an ASIL.

You use these terms to connect the item definition and safety goals to the requirements you develop throughout the lifecycle. ISO 26262 was published in 12 individual parts that cover the lifecycle from concept through decommissioning, and whichever part a team works in, its safety requirements trace back to the item definition and the safety goals.

Learn About ISO 26262

What Do SIL and ASIL Ratings Tell an Engineering Team?

A SIL or ASIL tells a team how much rigor a safety requirement needs, in risk reduction, hardware architecture and development process. The two scales come from different standards and answer that question in different ways.

What a SIL Tells a Team

Under IEC 61508, engineers assign one of four discrete SILs to a safety function, not a whole system. SIL 4 provides the highest risk reduction and SIL 1 the lowest. A SIL 1 function in low demand mode, for example, needs a risk reduction factor above 10 and up to 100.

Each SIL has a target failure measure. For a function in low demand mode, the target is the average probability of dangerous failure on demand (PFDavg). In high demand or continuous mode, it is the average frequency of dangerous failure per hour (PFH). Meeting the number is necessary but not sufficient, because IEC 61508 also grades architectural constraints and the systematic capability of software against the required SIL.

What an ASIL Tells a Team

An ASIL decides which ISO 26262 requirements apply to a safety goal and to the work beneath it. ISO 26262 uses four ASILs, A to D, with D the most stringent. Engineers rate a hazardous event that needs no ASIL as Quality Management (QM), meaning it has no functional safety requirements.

During HARA, engineers score each hazardous event on severity, probability of exposure and controllability by the driver or other road users. The classes are S0 to S3 for severity, E0 to E4 for exposure and C0 to C3 for controllability. For an ASIL D safety goal, engineers apply the strictest methods and tightest hardware targets to each derived requirement that keeps ASIL D.

Why SIL and ASIL Do Not Map One to One

SIL and ASIL do not map one to one because each is assigned to a different thing and reached by a different method. The scales have no normative mapping under ISO 26262, so you need separate evidence to claim ASIL D for a component certified at SIL 3.

Dimension SIL (IEC 61508) ASIL (ISO 26262)
Levels SIL 1 to SIL 4 QM, then ASIL A to ASIL D
Assigned to A safety function A safety goal and its derived requirements
Determined from Tolerable risk and other risk reduction measures Severity, exposure and controllability classes
Numeric targets PFDavg or PFH band per SIL Hardware architecture metrics and a random failure target per ASIL
Development process Systematic capability graded by required SIL Methods selected by ASIL

Neither scale is purely quantitative or purely qualitative. IEC 61508 allows quantitative and qualitative approaches to determining a SIL. ISO 26262 pairs a classification-based ASIL with quantitative hardware targets, such as a target for the single-point fault metric (SPFM) that is most stringent at ASIL D. On either scale, the rating decides how much verification evidence each derived requirement needs.

What Are the Steps of the Functional Safety Lifecycle?

Under IEC 61508, the functional safety lifecycle runs from concept and hazard analysis, through safety requirements, design and verification, to assessment, operation and decommissioning. Work under ISO 26262 follows the same broad progression. The phase names differ, but you can follow the work as one sequence.

The Phases From Concept to Decommissioning

You begin with the item’s definition and hazard assessment before deriving safety requirements and developing the design. The phases run from concept through decommissioning:

  1. Concept and item definition: You describe the item, its environment and its boundary.
  2. HARA: During HARA, you identify and rate hazardous events. Hazard analysis sets what each safety function has to do, while risk assessment sets how well it has to do it.
  3. Safety goals or overall safety requirements: Each rated hazard requires a top-level requirement with a SIL or ASIL.
  4. Functional safety concept: From the safety goals, you derive functional safety requirements and allocate them to architectural elements.
  5. Technical safety concept and allocation: Next, you refine them into technical safety requirements, the basis for hardware and software requirements.
  6. Hardware and software development: You design and build to the allocated requirements, with hardware techniques and measures graded against the safety integrity level.
  7. Integration and verification: During integration, you test and confirm with objective evidence that each requirement is fulfilled.
  8. Safety validation: At system or vehicle level, you confirm that the requirements for the intended use are met.
  9. Functional safety assessment and safety case: An independent assessor judges, from the safety case and its evidence, whether the standard’s objectives are met.
  10. Production, operation, service and decommissioning: You keep the safety requirements and their evidence current through production, operation, service and decommissioning.

You verify each phase’s outputs before the next phase uses them, as both standards require. The requirements you produce during safety-goal definition and functional and technical specification need to remain available for the assessor’s review.

How Each Hazard Becomes a Chain of Requirements

Engineers derive a safety goal from each hazard in HARA, refine that goal into functional safety requirements, and then derive technical safety requirements allocated to hardware and software. Each safety requirement derived from a safety goal initially has the ASIL of that safety goal. Engineers can lower the rating through ASIL decomposition by splitting a requirement into redundant requirements allocated to sufficiently independent architectural elements, but otherwise each keeps the original ASIL.

You link safety analyses to the same requirements, starting with the Failure Mode and Effects Analysis (FMEA) you use to identify and rank the ways a design might fail. With a fault tree analysis (FTA), you start from an unwanted top event and identify the combinations of faults that cause it. The results help you write new safety requirements or confirm existing ones.

At assessment, the assessor reviews those requirements and their verification evidence together. Under IEC 61508, the assessor has to be competent and adequately independent, and has to consider the activities and outputs of each lifecycle phase. The evidence an assessor reviews usually includes hazard analysis records, FMEA and FTA results, the traceability matrix and test reports.

Why Do Functional Safety Programs Struggle at Assessment Time?

Programs struggle at assessment when engineers change hazards, requirements or tests without updating the documents that describe them. When you change a requirement, design element or hazard rating, you have to re-check every linked safety analysis and test. Where the links between requirements, analyses and tests are kept in separate documents and spreadsheets, finding the items that need re-checking takes a manual search.

What Breaks When the Chain Is Kept in Separate Documents

The first failure is a change impact found late. Without links, a team either guesses which artifacts a change affects or re-checks everything, and in model-driven development the prevailing conservative approach is to re-analyse all models after every change. On a process plant, a change can also affect parts of the plant far from its source. Late discovery of non-compliance can force a redesign, for example when a SIL 3 function turns out to need two channels instead of one.

The second failure is a safety analysis that no longer matches the design. An FMEA or fault tree built against last quarter’s architecture still looks complete in its spreadsheet, because nothing in the file changes when the design does.

The third failure is evidence rebuilt by hand before each assessment. Assurance cases have usually been written by hand and reviewed through long, involved processes.

Why Linked Evidence Shortens Assessment Preparation

When each safety requirement stays linked to its analyses and tests in one place, a change shows which evidence needs re-checking, so the evidence isn’t rebuilt by hand before an assessment. Apex.AI, which builds Apex.OS, an ISO 26262 ASIL-D safety-certified software framework, reported in 2023 a 75% improvement in audit efficiency since onboarding Jama Connect®.

A Senior Functional Safety Engineer at Apex.AI described why automated traceability mattered to a team that had traced requirements manually before. “Having automated traceability was really important because we knew from previous experience how time-consuming it is trying to trace requirements to test manually and answer other artifacts.” Tracing requirements to tests by hand is the work that makes assessment preparation slow.

Learn About IEC 61508

How Jama Connect Supports Functional Safety

To keep the hazard-to-evidence chain current through change, Jama Connect, a web-based requirements management and traceability platform, links hazards, safety goals, functional and technical safety requirements, FMEA items and tests through a Traceability Information Model (TIM) that defines which relationships each item type needs. When a requirement or hazard rating changes, suspect links flag every downstream requirement and test case linked to the changed item for review, and impact analysis lists those items before you make the change. Requirements with no linked verification are listed in Live Trace Explorer™.

We provide pre-built industry frameworks for functional safety programs, including an automotive framework that supports ISO 26262 HARA workflows. For industrial machinery, the pre-configured framework is aligned with IEC 61508, ISO 13849 and IEC 62061, and nuclear energy programs working to IEC 61508 and IEC 61511 have their own pre-built framework. Out-of-the-box risk analysis reports, FMEA matrices with automatic Risk Priority Number calculation and traceability matrix exports produce the evidence an assessor reads from live project data. Process-sector and rail programs use the same traceability and suspect-link workflow.

Jama Intelligence adds AI-assisted capabilities within Jama Connect to help engineers improve requirements quality, generate draft test cases, and identify potential traceability gaps. For functional safety programs, this can help teams address ambiguous safety requirements earlier and support the development of verification tests and relationships between related engineering items. Engineers remain responsible for reviewing and approving AI-assisted outputs before incorporating changes into the engineering record.

Keeping Functional Safety Evidence Current Through Every Change

A safety case is useful for assessment only while its requirements and evidence match the design. Every change to a requirement, design element or hazard rating puts part of that evidence out of date. Before an assessment, the question to ask is which links have changed since the last review.

Jama Connect supports this workflow by flagging the safety requirements and tests a change touches while the change is being made. You can link a few safety goals to their requirements and tests in a free 30-day trial and see what one change flags.

Frequently Asked Questions About Functional Safety

Does Great Britain’s safety regulator expect a specific functional safety standard?

In Great Britain, the Health and Safety Executive (HSE) treats British Standard (BS) EN 61508 as the general benchmark of good practice for functional safety. For major-hazard sites under the Control of Major Accident Hazards (COMAH) regime, BS IEC 61511 is the preferred standard when HSE assesses a site’s safety report.

Can a safe state require the system to keep running?

Yes, for some equipment a safe state exists only as long as the equipment is continuously controlled, so stopping the controller would itself be unsafe. Equipment can also pass through several intermediate safe states between a hazardous condition and the final one, and each of those states needs its own requirements and verification.

Does functional safety cover cybersecurity?

Functional safety standards address hazards from malfunctions. For security, road vehicle teams use ISO/SAE 21434, while industrial automation teams use IEC 62443. Jama Connect supports automotive cybersecurity risk assessment with Threat Analysis and Risk Assessment (TARA) templates.

If I want to learn more about functional safety, what else should I read?

For guidance on structuring upstream and downstream links and keeping them current, read about traceability for regulated teams. Automotive teams can review the Functional Safety Kit datasheet for ISO 26262 process documentation.

This article was authored by Mario Maldari and published on November 20, 2026.